1.基本信息 Basic Information
1.1執(zhí)行標(biāo)準(zhǔn) According to (Standard)
GB/T14536.1-2008:《家用和類(lèi)似用途電自動(dòng)控制器 第1部分:通用要求》
IEC 730-1:1994 Automatic electrols for household and similar use. Part 1:General requirements
GB/T14536.10-2008:《家用和類(lèi)似用途電自動(dòng)控制器 溫度敏感控制器的特殊要求》
IEC 730-2-9-1992:Automatic electrical controls for household and similar use Particuar
requirements for temperature sensing controls
JB/T 3751-1997:《家用和類(lèi)似用途雙金屬溫度控制器》
JB/T 3751-1997:Bi-meral temperature controls for household and similar use
1.2構(gòu)造Structure
1.2.1. 分類(lèi) Classification
屬于溫度固定的雙金屬碟片瞬動(dòng)式溫度控制器。
They are temperature-fixed bi-metal Snap-Action temperature controller
1.2.2.接地方式 Method Of Earth
通過(guò)溫控器金屬外蓋與設(shè)備接地金屬部件相連。
By means of the metal cup of thermostat connected in the earthing meral part.
1.2.3.外觀及尺寸Appearance
外觀應(yīng)加工良好,無(wú)有損于性能及商品價(jià)值的傷、裂、變形、毛刺、污漬等缺陷。
The appearance should be processed well, without any defect effecting the performance or
value of the merchandise such as strain,crach,rust,distortion,besmirch,ete.
1.3動(dòng)作方式Action Forms
■ 室溫下觸點(diǎn)接通(nc),溫度上升觸點(diǎn)斷開(kāi),溫度降低觸點(diǎn)恢復(fù)接通。
Normal close:Cut out at temperature rise,cut in at temperature decreasing.
□室溫下觸點(diǎn)接通(nc),溫度下降觸點(diǎn)斷開(kāi),溫度上升觸點(diǎn)恢復(fù)接通。
Normal close:Cut out at temperature decreasing,cut in at temperature rise.
□室溫下觸點(diǎn)斷開(kāi)(no),溫度上升觸點(diǎn)接通,溫度降低觸點(diǎn)恢復(fù)斷開(kāi)。
Normal open:Cut in at temperature rise,cut out at temperature decreasing.
□室溫下觸點(diǎn)斷開(kāi)(no), 溫度下降觸點(diǎn)接通,溫度上升觸點(diǎn)恢復(fù)斷開(kāi)。
Normal open:Cut in at temperature decreasing,cut out at temperature rise.
□室溫下觸點(diǎn)接通(nc),溫度上升觸點(diǎn)斷開(kāi),溫度降低手動(dòng)復(fù)位接通。
Normal close:Cut out at temperature rise,manual reset at temperature decreasing.
1.4.型號(hào)命名方式Nomenclature of Type
TM 22 130 A 5 20 10A 1 R 4 D
Ⅰ Ⅱ Ⅲ Ⅳ Ⅴ Ⅵ Ⅶ Ⅷ Ⅸ Ⅹ Ⅺ
Ⅰ.工廠(chǎng)品牌(TM縮寫(xiě))Factoy Brand(TM Abbreviation)
Ⅱ.工廠(chǎng)設(shè)計(jì)代號(hào):(本廠(chǎng)為22等)Design Code:22
Ⅲ.動(dòng)作溫度:OFF及ON溫度中的較高值Operating tempersture,the higher value
of OFF temp.and ON temp
Ⅳ.動(dòng)作溫度特性:Temperature Characteristics
A-常閉型:斷開(kāi)溫度高于接通溫度
A-Normal type:OFF temperature higher than ON temperature
K-常開(kāi)型:斷開(kāi)溫度低于接通溫度
K-K type:ON temperature higher htan OFF temperature
M-手動(dòng)復(fù)位型:溫控器在常溫下接通,斷開(kāi)后,不能自動(dòng)復(fù)位,需要手動(dòng)進(jìn)行復(fù)位
M-Manual reset type:The thermostat switches on at room temperature and it won be able
to reset after switching off
O-一次動(dòng)作性:溫控器在室溫下接通,溫控器斷開(kāi)后,不能復(fù)位
O-One-shot type:The thermostat switches on at room temperature and it wont be able to
Reset switching off
Ⅴ.標(biāo)稱(chēng)動(dòng)作溫度誤差值:Open temperature difference
2表示Said±2℃
3表示Said±3℃
5表示Said±5℃
10表示Said±10℃
Ⅵ.動(dòng)作溫度與復(fù)位溫度差值,2位Open temperature or Rstet temperature the difference
手動(dòng)復(fù)位型無(wú)此項(xiàng)數(shù)字 The non-manual reset
Ⅶ.額定阻性負(fù)載電流:10A,15A,16A Current Rating:5A,10A,15A
Ⅷ.端子姿態(tài)Terminal Angle
1:水平Horizontal
2:垂直Vertical
3:垂直/45°Vertical/45°
4:水平/45°Horizontal/45°
5:45°/45°
6:水平/垂直Horizontal/Vertical
7:其它類(lèi)型角度
3/
Ⅸ.端子類(lèi)型Temrinal Type
N:187系列端子(4.8×0.5)187Series
M:187系列端子(4.8×0.8)187Series
R:250系列端子(6.3×0.8)250Series
F:非標(biāo)端子Not Criterion
Ⅹ.固定形式Holder Type
1:活動(dòng)固定器Free Holder
2:無(wú)固定器 Without the Holder
3:45°固定器45°Holder
4:90°固定器90°Holder
5:180°固定器180°Holder
Ⅺ.絕緣殼體Insul ating Material
D:電木Free Holder
E:陶瓷Without the Holder
P:PPS
2.主要性能Primary Performance
2.1.動(dòng)作溫度Operating Temperature
2.1.1.溫度特性Characteristic
斷電溫度: 130±5℃
接通溫度: 標(biāo)準(zhǔn)復(fù)位
2.1.2. 測(cè)試方法Test method
把溫控器夾在測(cè)試區(qū)內(nèi),等待測(cè)溫區(qū)的溫度平衡后,開(kāi)始測(cè)試。測(cè)試爐內(nèi)以空氣作為加熱
介質(zhì),在測(cè)溫區(qū)放置溫度計(jì)或溫度傳感器。在溫度進(jìn)入動(dòng)作溫度公差范圍前2K開(kāi)始,以小于1K/min的溫度變化速率進(jìn)行加溫或降溫,其間必須進(jìn)行攪拌,使溫度分布充分均勻;測(cè)溫區(qū)溫
度分布均勻性在±0.4K以?xún)?nèi)。
測(cè)試裝置可設(shè)置通斷顯示裝置。溫控器兩接線(xiàn)端子間電壓大于5V,通過(guò)試樣電流大于10mA。